Anion
Exchangers
|
|
UltraSep ES SAX W (Anorganic ions according to DIN 38405)
|
|
|
These
anion exchangers are so called „permanently loaded“ ion exchangers. They
exhibit the excellent performance of silicas and the good stability of RP-phases, which leads to low
costs.
|
|
Stability
of UltraSep ES SAXW with phthalic acid/TRIS buffer (1.25/2.5 mM) at pH 6.4
|
|
|
Permanently
loaded ion exchangers are not only useful to separate inorganic ions (see Application ANION1)
but also to
separate natural products with aqueous buffers (nucleotides).
They cannot be used with organic-aqueous eluents.
Our permanently loaded ion
exchangers are easily to regenerate. For this, we offer a special solution or a
regeneration in our firm. If
there is a need to chromatograph aqueous solutions highly contaminated
with organic material, we recommend to use additionally a RP precolumn (length
33 mm) in front of the precolumn cartridge
( ANION2 Tap water from Berlin). By
lowering of the strength of the
eluent,
phosphate appears between nitrite and bromide without the necessity to increase the pH noticeably
In this way, there are good conditions for the conductivity
detection too. Furthermore, fluoride is well separated from the injection peak (see Application ANION3). |
|
|
|
|
|
UltraSep ES SAX W Quick Columns
|
|
|
See Applications ANION5 and
ANION6
|
|
UltraSep ES SAX W33 (Determination
of
ascorbic acid)
|
|
|
See Applications ANION9
|
|
UltraSep ES SAX NN (Rapid determination of
nitrite, nitrate, and bromide in drinking water and foodstuffs)
|
|
|
By this exchanger concentrations
of nitrite and nitrate can be determined considerably faster and more sensitive
than with customary methods. Nitrate, which can be determined by the photometric
method only relatively insensitively, is determined by chromatography at 220 nm
without previous enrichment to 0.1 mg/l. Bromide is determined at 210 nm with
high sensitivity.
Iodide
can be determined also directly at 225 nm. For
a quick determination of iodide you can use a column of UltraSep
ES SAX NN with a length of 33 mm.
The
selectivity and rapidity of the determination (phosphoric acid as eluent) can be
changFor columns with endcapped packings an additional charge of 10.00
€ is calculated. ed by the pH value (at best pH 3 – 5). Furthermore, the velocity
of elution can also be varied by the concentration of phosphoric acid (at best
10 – 30 mM; see Application ANION4).
|
|
|
|
|
UltraSep ES RP NN (Determination of
nitrite, nitrate, bromate and bromide in drinking water and foodstuffs)
|
|
|
See Applications ANION7 and ANION8 |
|
Examples of
Analyzed Compounds |
Analyzed in Application
(AN = ANION)
|
Go to |
|
Ascorbic
acid |
AN9 |
ANION1 |
|
Bromate |
AN7,
AN8 |
ANION2
|
|
Bromide |
AN1,
AN3, AN4, AN5, AN6, AN7 |
ANION3
|
|
Carbonate
|
AN2 |
ANION4
|
|
Chloride
|
AN1,
AN2, AN3, AN5, AN6 |
ANION5
|
|
Fluoride |
AN3 |
ANION6
|
|
Nitrate |
AN1,
AN3, AN4, AN5, AN6, A7 |
ANION7 |
|
Nitrite |
AN1,
AN3, AN4, AN5, AN6, A7 |
ANION8 |
|
Phosphate
|
AN3,
AN6 |
ANION9 |
|
Sulfate |
AN1,
AN2, AN3, AN5, AN6 |
|
|
|
|
|
|
|
|
|
COLUMNS
and PRICES
(€) |
|
Column size (mm) |
150 x 3 |
125 x 3 |
60 x 3 |
33 x 3 |
UltraSep ES SAX W |
|
270.00 |
|
|
UltraSep ES SAX W Guard
column RP 18 * |
|
|
|
125.00 |
UltraSep ES SAX W QC |
|
|
255.00 |
250.00 |
UltraSep ES SAX QCM |
|
270.00 |
|
|
UltraSep ES SAX NN |
|
|
265.00 |
245.00 |
UltraSep ES RP NN |
240,00 |
240,00 |
|
|
UltraSep ES SAX W33 |
|
295,00 |
|
|
*
Recommended as precolumn for samples with high content of organic substances.
|
Size (mm)
|
|
|
|
10 x 3 |
5 x 3 *** |
|
Precolumn
cartridges
(Price per pack = 5 pieces) |
|
170.00 |
170.00 |
Activator for ES SAX W (1
ml) |
12.00 |
|
|
Regeneration solution (30 ml) for regeneration by customer |
33.00 |
|
|
***
Only for UltraSep ES SAX W QC. |
| |
Home
Survey
About
SEPSERV
Catalogue
HPLC Columns
Special
Columns
Environment
Food
Stuffs
Biochemistry
Clinical
Chemistry
.Pharmaceuticals
Chiralic
Analysis
Ion
Exchangers
OtherlSpeciallColumns
SelectivitylPacklTRIS
Ordering
|